Description
The BELDEN INC. 10GX53F D151000 is a Category 6A foil-shielded unshielded twisted pair (F/UTP) cable rated for plenum (CMP) environments. It is constructed as a 4-pair cable and supplied on a reel in blue jacket. Cat6a cabling supports 10 Gigabit Ethernet at frequencies up to 500 MHz, making it suitable for high-bandwidth network infrastructure in commercial and institutional buildings. This cable is installed by licensed low-voltage electricians and structured cabling technicians in air-handling spaces where plenum-rated materials are required by fire code.
This cable is intended for horizontal runs and backbone installations in plenum air-handling spaces such as raised-floor data centers, above-ceiling cable trays, and open-office structured cabling systems. The CMP plenum rating satisfies fire and smoke propagation requirements for air-handling spaces as defined under the National Electrical Code. The blue jacket provides visual identification during installation and patch documentation. Reel packaging is suited to bulk pulls for large commercial or campus network projects.
Key Features
- Category 6A performance supports 10GBase-T Ethernet applications
- F/UTP construction provides foil shielding for improved alien crosstalk (AXT) rejection
- CMP plenum rating meets NEC requirements for installation in air-handling spaces
- 4-pair configuration follows standard TIA-568 horizontal cabling architecture
- Blue jacket aids in cable identification and color-coded infrastructure management
- Reel packaging supports high-volume bulk cable pulls
Compatibility
Designed as an OEM-style plenum Cat6a cable suitable for structured cabling systems requiring F/UTP Category 6A performance in plenum-rated pathways.
Installation Notes
Installation should be performed by a licensed low-voltage electrician or registered communications distribution designer (RCDD) in accordance with ANSI/TIA-568 and applicable NEC articles for communications wiring. De-energize and lock out all adjacent powered circuits before working in shared cable pathways. Maintain minimum bend radius and avoid exceeding the cable pull tension rating to prevent degradation of the foil shield and pair geometry. Terminate to Cat6a-rated jacks, patch panels, and connectors only to preserve channel performance.
Technical Specifications
- Cable Category: Cat6a
- Pair Count: 4-pair
- Shield Type: F/UTP (Foil Shielded, Unshielded Twisted Pair)
- Plenum Rating: CMP
- Jacket Color: Blue
- Packaging: Reel
- Unit of Measure: EA
- Quantity Per Unit: 1
Standard Information
- Brand: BELDEN INC.
- Manufacturer Part Number: 10GX53F D151000